Cleanroom, HVAC & Filtration Validation

Primionics provides cleanroom, HVAC and filtration measurement technologies in India for continuous environmental monitoring, portable and remote particle counting, airflow and differential-pressure verification, aerosol generation, installed HEPA/ULPA filter integrity and filter development testing. The portfolio supports cleanroom classification, routine monitoring, recovery studies, HVAC performance verification, filter leakage assessment and contamination investigations.

Explore engineering solutionsView solution family

Engineering priorities

Traceable Measurement for Contamination Control and Air-System Performance

Continuous Environmental Monitoring

Remote particle sensors, environmental channels, configurable alarms and historical trends provide continuous evidence of environmental performance between periodic qualification activities.

Representative Particle Sampling

Sampling location, particle size, sample flow, tubing length, transport loss and room operating state directly influence particle-counting results and therefore require deliberate measurement planning.

Airflow and Installed-Filter Integrity

Installed HEPA and ULPA systems require a controlled aerosol challenge, representative upstream reference, systematic downstream assessment and documented operating conditions for defensible integrity evidence.

Core engineering capabilities

Cleanroom Monitoring, Airflow Measurement and Filtration Capabilities

Continuous Cleanroom Monitoring Systems

Remote particle sensors, monitoring software, configurable alarms, historical trends and integration of temperature, humidity and pressure channels for continuous cleanroom performance evidence.

Portable Particle Counting

Portable and handheld particle counters for cleanroom classification, qualification support, recovery measurement, troubleshooting and location-specific environmental checks.

Airflow & Environmental Measurement

Air velocity, volume flow, differential pressure and environmental measurement for cleanrooms, controlled environments and HVAC performance verification.

Aerosol Generation & Filter Testing

Aerosol generators, photometers, dilution and conditioning technologies, filter scanning and dedicated filter-test systems.

Solution portfolio

Integrated Measurement Solutions for Controlled Environments

Continuous Cleanroom Monitoring Systems

Fixed remote particle sensors, centralized acquisition, configurable alarms, event review and time-stamped historical records for continuous environmental monitoring.

Explore solution

Portable Particle Counting

Portable instruments for cleanroom classification, troubleshooting, recovery studies, filter verification and location-specific investigations.

Explore solution

Airflow & Room Performance Instruments

Anemometers, micromanometers and environmental instruments for air velocity, volume flow, differential pressure, temperature and humidity measurement.

Explore solution

Aerosol Challenge and Integrity-Test Systems

Controlled challenge-aerosol generation and photometric detection for HEPA/ULPA integrity testing, leak localisation and system verification.

Explore solution

Filter & Media Test Systems

Test platforms for filter media, filter elements and high-flow filters across defined development, qualification and production test conditions.

Explore solution

Environmental Monitoring and Data Integration

Centralized dashboards, alarm notifications, historical trends, reports and interfaces for cleanroom and facility-monitoring systems.

Explore solution

Industry applications

Cleanroom, HVAC and Filtration Application Areas

Pharmaceutical and biotechnology cleanrooms
Semiconductor fabs and advanced packaging
Hospitals and sterile processing areas
Cleanroom validation and certification services
HVAC commissioning and filter integrity testing
Filter manufacturing and research laboratories
Technical design priorities

Representative Sampling, Controlled Test Conditions and Traceable Evidence

Representative Particle Sampling

Critical locations, particle sizes, sample flow, tubing length and transport loss matched to the room and monitoring objective.

Alarm, Trend and Event Management

Time-stamped particle and environmental data, alert levels, alarm delays, user access, event review and retained trends support ongoing environmental assessment.

Installed-Filter Integrity Testing

Controlled aerosol generation, dilution, photometer response, scan methodology and airflow measurement are central to HEPA/ULPA leakage testing.

Qualification and Measurement Records

Calibration status, test conditions and structured records support work performed to ISO 14644, EN 1822, ISO 29463 and site-specific procedures where applicable.